PWR-IE65W-PC-DC工业电源



 

PWR-IE65W-PC-DC工业电源
 

  1. 输入电压:24V DC

  2. 输出电压:24V DC

  3. 输出功率:65W

  4. 效率:通常高于90%

  5. 工作温度:-20°C 至 +70°C

  6. 冷却方式:自然冷却

  7. 保护功能:过压保护、过流保护、短路保护、过热保护

  8. 尺寸:标准工业尺寸,具体尺寸需参考产品手册

  9. 认证:符合CE、RoHS等国际标准

Part #

Product description

PWR-IE50W-AC-L=

50W AC to DC power supply

PWR-IE50W-AC=

50W AC to DC power supply

PWR-IE50W-AC-IEC=

50W AC to DC power supply with IEC connector (IEC 60320 C14)

PWR-IE65W-PC-AC=

65W AC to DC power supply

PWR-IE65W-PC-DC=

65W DC to DC power supply

PWR-IE170W-PC-AC=

170W AC to DC power supply

PWR-IE170W-PC-DC=

170W DC to DC power supply

PWR-IE240W-PCAC-L=

240W AC to DC power supply

PWR-IE480W-PCAC-L=

480W AC to DC power supply

 

Part number

Product image

Product description

PoE / PoE+ support

 

     

PWR-IE65W-PC-DC=

Related image, diagram or screenshot

65W Low DC to DC power supply

Yes

 

     
 

Product ID

Rated nominal input operating range

Supported input voltage operating range

Typical efficiency

Inrush current at 25C ambient

Remarks

PWR-IE50W-AC-L=

AC 100-240V/1.2A, 50-60Hz

AC 90-264V

88%

< 35A @ 115VAC and 70A @ 230VAC

Not approved for hazardous location installations

PWR-IE50W-AC=

AC 100-240V/1.25A, 50-60Hz

or

DC 125-250V/1.25A

AC 90-264V

or

DC 106-300V

80%

< 35A @ 115VAC and 70A @ 230VAC

Approved for Class 1, Div 2/Zone 2 installations

PWR-IE50W-AC-IEC=

AC 100-240V/1.25A, 50-60Hz

AC 90-264V

80%

< 35A @ 115VAC and 70A @ 230VAC

Not approved for hazardous location installations

PWR-IE65W-PC-AC=

AC 100-240V/1.4A, 50-60Hz

or

DC 125-250V/1.0A

AC 90-264V

or

DC 106-300V

85%

< 35A @ 115VAC and 70A @ 230VAC

Approved for Class 1, Div 2/Zone 2 installations

CSA certified

PWR-IE65W-PC-DC=

DC 24-48VDC/4.5A

DC 18-60V

92%

4A@24VDC

Approved for Class 1, Div 2/Zone 2 installations

PWR-IE170W-PC-AC=

AC 100-240V/2.3A, 50-60Hz

or

DC 125-250V/2.1A

AC 90-264V

or

DC 106-300V

88%

< 35A @ 115VAC and 70A @ 230VAC

Approved for Class 1,

Div 2/Zone 2 installations

CSA certified

PWR-IE170W-PC-DC=

DC 12-54V/23A

DC 10.8-60V

88%

17.3A @ 12VDC

Approved for Class 1, Div 2/Zone 2 installations

PWR-IE240W-PCAC-L=

AC 100-240V/3.5A, 50-60Hz

AC 90-264V

91%

< 35A @ 115VAC

and 230VAC

Not approved for hazardous location installations

PWR-IE480W-PCAC-L=

AC 100-240V/6A, 50-60Hz

AC 90-264V

92%

< 35A @ 115VAC

and 230VAC

Not approved for hazardous location installations

 

Product ID

Nominal output voltage / adjustment range

Max output power

Holdup time at 100% load

Protections

PWR-IE50W-AC-L=

24VDC / 24-28VDC, 2.1A

50W

20ms

Over voltage protection

Over current protection

Over temperature protection

Short circuit protection

PWR-IE50W-AC=

24VDC, 2.1A

50W

20ms

PWR-IE50W-AC-IEC=

24VDC, 2.1A

50W

20ms

PWR-IE65W-PC-AC=

54VDC, 1.2A

65W

10ms

PWR-IE65W-PC-DC=

54VDC, 1.2A

65W

 

PWR-IE170W-PC-AC=

54VDC, 3.2A

170W

20ms

PWR-IE170W-PC-DC=

54VDC, 3.2A

170W

9ms (@10.8VDC) to 25.9ms (@ 60VDC)

PWR-IE240W-PCAC-L=

54VDC / 48-56VDC, 4.5A

240W

20ms

PWR-IE480W-PCAC-L=

54VDC / 48-56VDC, 8.9A

480W

20ms

 

Product ID

IP rating

Operating temperature

Storage temperature

Power derating

Operating humidity

PWR-IE50W-AC-L=

IP20

-20°C to +70°C

-40°C to +85°C

> 55°C de-rate power by 3.33%/°C

< -10°C de-rate power by 2%/°C

5 to 95% RH

(non-condensing)

PWR-IE50W-AC=

IP20

-40°C to +75°C

-40°C to +85°C

No derating

<95% RH

(non-condensing)

PWR-IE50W-AC-IEC=

IP20

-20°C to +70°C

-40°C to +85°C

No derating

<95% RH

(non-condensing)

PWR-IE65W-PC-AC=

IP20

-40°C to +75°C

-40°C to +85°C

No derating

<95% RH

(non-condensing)

PWR-IE65W-PC-DC=

IP20

-40°C to +75°C

-40°C to +85°C

No derating

<95% RH

(non-condensing)

PWR-IE170W-PC-AC=

IP20

-40°C to +75°C

-40°C to +85°C

No derating

<95% RH

(non-condensing)

PWR-IE170W-PC-DC=

IP20

-40°C to +75°C

-40°C to +85°C

No derating

<95% RH

(non-condensing)

PWR-IE240W-PCAC-L=

IP20

-40°C to +80°C

-40°C to +85°C

Vertical mounting:

> 50°C de-rate power by 2.5%/°C

Horizontal mounting:

> 40°C de-rate power by 2.5%/°C

5 to 95% RH

(non-condensing)

PWR-IE480W-PCAC-L=

IP20

-40°C to +75°C

-40°C to +85°C

Vertical mounting:

> 50°C de-rate power by 2.5%/°C

> 70°C de-rate power by 5%/°C

5 to 95% RH

(non-condensing)

 

Product ID

Electric safety

EMC/ Industry standards

PWR-IE50W-AC-L=

CE (EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC)

UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1

UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1

UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01

CB scheme to IEC 60950-1, LPS

NEC Class 2

EN 61000-3-2 Class A, EN 61000-3-3

EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4,

EN 61204-3, EN 55035 (EN 61000-4-2,3,4,5,6,8,11 )

CISPR 32, EN 55032, CISPR 11, EN 55011,

FCC 47 CFR part 15B

PWR-IE50W-AC=

EN60950-1: 2006+A1: 2010+A11: 2009 +A12:

2011+A2: 2013, EN61131-2: 2007

EN62368-1: 2014 + A11: 2017

IEC60950-1: 2005+A1: 2009+A2: 2013

IEC62368-1: 2014

EN 60079-0:2012 + A11:2013, EN 60079-15:2010

CE

EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-8, EN 61000-4-11

IEC61000-4-11, IEC61000-4-12, IEC61000-4-16

CISPR 32, EN 55032, CISPR35, EN55035

FCC 47 CFR part 15B

PWR-IE50W-AC-IEC=

EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, EN62368-1: 2014 + A11: 2017

CE

EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-8, EN 61000-4-11

IEC61000-4-11, IEC61000-4-12, IEC61000-4-16

CISPR 32, EN 55032, CISPR35, EN55035

FCC 47 CFR part 15B

PWR-IE65W-PC-AC=

EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, EN61131-2: 2007 EN62368-1: 2014 + A11: 2017 IEC60950-1: 2005+A1: 2009+A2: 2013 IEC62368-1: 2014

UL 508

Class 1, Div 2/ Zone 2 Hazardous location

CE

UL60950-1 and CSA60950-1 certified

EN61000-4-2, EN61000-4-3, EN61000-4-4,

EN61000-4-5, EN61000-4-6, EN61000-4-8, IEC61000-3-3, EN/IEC61000-4-11, IEC61000-4-12, EN61131-2: 2007

CISPR 32, EN 55032, CISPR35, EN55035

FCC47 CFR part 15B

IEC 61850-3, IEEE1613

EN 61000-6-4, EN 61000-6-2

PWR-IE65W-PC-DC=

EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013

UL 508

Class 1, Div2/ Zone 2 Hazardous Location

CCC

CE

EN61000-4-2, EN61000-4-3, EN61000-4-4,

EN61000-4-5, EN61000-4-6, EN61000-4-8,

CISPR 32, EN 55032, CISPR35, EN55035

FCC 47 CFR part 15B

IEC 61850-3, IEEE1613

EN 61000-6-4, EN 61000-6-2

PWR-IE170W-PC-AC=

IEC60950-1: 2005+A1: 2009+A2: 2013 EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013,

KCC mark, BSMI mark, CCC, CB Scheme,

Class 1, Div2/ Zone 2 Hazardous Location

CE

UL60950-1and CSA60950-1 certified

EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, IEC61000-3-3, EN/IEC61000-4-11, IEC61000-4-12

CISPR 32, EN 55032, CISPR35, EN55035

47 CFR FCC part 15B

EN61131-2: 2007

IEC 61850-3, IEEE 1613

EN50121-4:2016

PWR-IE170W-PC-DC=

EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013

UL 508

Class 1, Div 2/Zone 2 Hazardous location

CE

EN61000-4-2, EN61000-4-3, EN61000-4-4,

EN61000-4-5, EN61000-4-6, EN61000-4-8,

CISPR 32, EN 55032, CISPR35, EN55035

FCC 47 CFR part 15B

IEC 61850-3, IEEE1613

EN 61000-6-4, EN 61000-6-2

PWR-IE240W-PCAC-L=

SIQ Bauart to EN 60950-1

UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme to IEC 60950-1

UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)

CSA C22.2 No. 107.1-01 (File No. 181564)

EN 61000-3-2 Class A, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2,

EN 61204-3, EN 55024 (EN 61000-4-2 LEVEL 3, Performance Criteria A and EN 61000-4-3,4,5,6,8,11,12)

CISPR 32, EN 55032, CISPR35, EN55035

FCC 47 CFR Part15B

PWR-IE480W-PCAC-L=

SIQ Bauart to EN 60950-1

UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme to IEC 60950-1

UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355)

CSA C22.2 No. 107.1-01 (File No. 181564)

EN 61000-3-2 Class A, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2,

EN 61204-3, EN 55024 (EN 61000-4-2 LEVEL 3, Performance Criteria A and EN 61000-4-3,4,5,6,8,11,12)

CISPR 32, EN 55032, CISPR35, EN55035

FCC 47 CFR Part 15B

 

Product ID

Dimensions (W x H x D)

Unit weight

MTBF (Telcordia SR-332)

PWR-IE50W-AC-L=

30 mm x 75 mm x 89.5 mm

1.18 in x 2.95 in x 3.52 in

0.39 lb (0.18 kg)

2,255,613 hours

PWR-IE50W-AC=

51 mm x 118 mm x 148 mm

2 in x 4.64 in x 5.82 in

1.41 lb (0.64 kg)

1,662,359 hours

PWR-IE50W-AC-IEC=

51 mm x 118 mm x 148 mm

2 in x 4.64 in x 5.82 in

1.43 lb (0.65 kg)

1,662,359 hours

PWR-IE65W-PC-AC=

66 mm x 148 mm x 118 mm

2.5 in x 5.82 in x 4.64 in

2.64 lb (1.2 kg)

2,488,401 hours

PWR-IE65W-PC-DC=

66 mm x 150 mm x 117 mm

2.59 in x 5.90 in x 4.60 in

2.60 lb (1.18 kg)

4,802,673 hours

PWR-IE170W-PC-AC=

96 mm x 150 mm x 146 mm

3.77 in x 5.90 in x 5.74 in

3.88 lb (1.76 kg)

2,384,975 hours

PWR-IE170W-PC-DC=

114 mm x 150 mm x 146 mm

4.48 in x 5.90 in x 5.74 in

3.68 lb (1.67 kg)

2,164,641 hours

PWR-IE240W-PCAC-L=

85 mm x 121 mm x 124.1 mm

3.34 in x 4.76 in x 4.88 in

2.11 lb (0.96 kg)

1,579,900 hours

PWR-IE480W-PCAC-L=

144 mm x 121 mm x 118.6 mm

5.66 in x 4.76 in x 4.66 in

3.02 lb (1.37 kg)

1,058,750 hours