PWR-IE170W-PC-AC工业电源
PWR-IE170W-PC-AC电源

PWR-IE170W-PC-AC电源
-
输入电压:100-240V AC
-
输出电压:24V DC
-
输出功率:170W
-
效率:通常高于90%
-
工作温度:-20°C 至 +70°C
-
冷却方式:自然冷却
-
保护功能:过压保护、过流保护、短路保护、过热保护
-
尺寸:标准工业尺寸,具体尺寸需参考产品手册
-
认证:符合CE、RoHS等国际标准
产品规格
Part # |
Product description |
PWR-IE50W-AC-L= |
50W AC to DC power supply |
PWR-IE50W-AC= |
50W AC to DC power supply |
PWR-IE50W-AC-IEC= |
50W AC to DC power supply with IEC connector (IEC 60320 C14) |
PWR-IE65W-PC-AC= |
65W AC to DC power supply |
PWR-IE65W-PC-DC= |
65W DC to DC power supply |
PWR-IE170W-PC-AC= |
170W AC to DC power supply |
PWR-IE170W-PC-DC= |
170W DC to DC power supply |
PWR-IE240W-PCAC-L= |
240W AC to DC power supply |
PWR-IE480W-PCAC-L= |
480W AC to DC power supply |
Part number |
Product image |
Product description |
PoE / PoE+ support |
|
|||
PWR-IE170W-PC-AC= |
170W AC to DC or High DC to DC power supply |
Yes |
|
|
Product ID |
Rated nominal input operating range |
Supported input voltage operating range |
Typical efficiency |
Inrush current at 25C ambient |
Remarks |
PWR-IE50W-AC-L= |
AC 100-240V/1.2A, 50-60Hz |
AC 90-264V |
88% |
< 35A @ 115VAC and 70A @ 230VAC |
Not approved for hazardous location installations |
PWR-IE50W-AC= |
AC 100-240V/1.25A, 50-60Hz or DC 125-250V/1.25A |
AC 90-264V or DC 106-300V |
80% |
< 35A @ 115VAC and 70A @ 230VAC |
Approved for Class 1, Div 2/Zone 2 installations |
PWR-IE50W-AC-IEC= |
AC 100-240V/1.25A, 50-60Hz |
AC 90-264V |
80% |
< 35A @ 115VAC and 70A @ 230VAC |
Not approved for hazardous location installations |
PWR-IE65W-PC-AC= |
AC 100-240V/1.4A, 50-60Hz or DC 125-250V/1.0A |
AC 90-264V or DC 106-300V |
85% |
< 35A @ 115VAC and 70A @ 230VAC |
Approved for Class 1, Div 2/Zone 2 installations CSA certified |
PWR-IE65W-PC-DC= |
DC 24-48VDC/4.5A |
DC 18-60V |
92% |
4A@24VDC |
Approved for Class 1, Div 2/Zone 2 installations |
PWR-IE170W-PC-AC= |
AC 100-240V/2.3A, 50-60Hz or DC 125-250V/2.1A |
AC 90-264V or DC 106-300V |
88% |
< 35A @ 115VAC and 70A @ 230VAC |
Approved for Class 1, Div 2/Zone 2 installations CSA certified |
PWR-IE170W-PC-DC= |
DC 12-54V/23A |
DC 10.8-60V |
88% |
17.3A @ 12VDC |
Approved for Class 1, Div 2/Zone 2 installations |
PWR-IE240W-PCAC-L= |
AC 100-240V/3.5A, 50-60Hz |
AC 90-264V |
91% |
< 35A @ 115VAC and 230VAC |
Not approved for hazardous location installations |
PWR-IE480W-PCAC-L= |
AC 100-240V/6A, 50-60Hz |
AC 90-264V |
92% |
< 35A @ 115VAC and 230VAC |
Not approved for hazardous location installations |
Product ID |
Nominal output voltage / adjustment range |
Max output power |
Holdup time at 100% load |
Protections |
PWR-IE50W-AC-L= |
24VDC / 24-28VDC, 2.1A |
50W |
20ms |
Over voltage protection Over current protection Over temperature protection Short circuit protection |
PWR-IE50W-AC= |
24VDC, 2.1A |
50W |
20ms |
|
PWR-IE50W-AC-IEC= |
24VDC, 2.1A |
50W |
20ms |
|
PWR-IE65W-PC-AC= |
54VDC, 1.2A |
65W |
10ms |
|
PWR-IE65W-PC-DC= |
54VDC, 1.2A |
65W |
|
|
PWR-IE170W-PC-AC= |
54VDC, 3.2A |
170W |
20ms |
|
PWR-IE170W-PC-DC= |
54VDC, 3.2A |
170W |
9ms (@10.8VDC) to 25.9ms (@ 60VDC) |
|
PWR-IE240W-PCAC-L= |
54VDC / 48-56VDC, 4.5A |
240W |
20ms |
|
PWR-IE480W-PCAC-L= |
54VDC / 48-56VDC, 8.9A |
480W |
20ms |
Product ID |
IP rating |
Operating temperature |
Storage temperature |
Power derating |
Operating humidity |
PWR-IE50W-AC-L= |
IP20 |
-20°C to +70°C |
-40°C to +85°C |
> 55°C de-rate power by 3.33%/°C < -10°C de-rate power by 2%/°C |
5 to 95% RH (non-condensing) |
PWR-IE50W-AC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
PWR-IE50W-AC-IEC= |
IP20 |
-20°C to +70°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
PWR-IE65W-PC-AC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
PWR-IE65W-PC-DC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
PWR-IE170W-PC-AC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
PWR-IE170W-PC-DC= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
No derating |
<95% RH (non-condensing) |
PWR-IE240W-PCAC-L= |
IP20 |
-40°C to +80°C |
-40°C to +85°C |
Vertical mounting: > 50°C de-rate power by 2.5%/°C Horizontal mounting: > 40°C de-rate power by 2.5%/°C |
5 to 95% RH (non-condensing) |
PWR-IE480W-PCAC-L= |
IP20 |
-40°C to +75°C |
-40°C to +85°C |
Vertical mounting: > 50°C de-rate power by 2.5%/°C > 70°C de-rate power by 5%/°C |
5 to 95% RH (non-condensing) |
Product ID |
Electric safety |
EMC/ Industry standards |
PWR-IE50W-AC-L= |
CE (EMC Directive 2004/108/EC and Low Voltage Directive 2006/95/EC) UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 UL/cUL listed to UL 508 and CSA C22.2 No. 107.1-01 CB scheme to IEC 60950-1, LPS NEC Class 2 |
EN 61000-3-2 Class A, EN 61000-3-3 EN 61000-6-1, EN 61000-6-2, EN 61000-6-3, EN 61000-6-4, EN 61204-3, EN 55035 (EN 61000-4-2,3,4,5,6,8,11 ) CISPR 32, EN 55032, CISPR 11, EN 55011, FCC 47 CFR part 15B |
PWR-IE50W-AC= |
EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, EN61131-2: 2007 EN62368-1: 2014 + A11: 2017 IEC60950-1: 2005+A1: 2009+A2: 2013 IEC62368-1: 2014 EN 60079-0:2012 + A11:2013, EN 60079-15:2010 CE |
EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-8, EN 61000-4-11 IEC61000-4-11, IEC61000-4-12, IEC61000-4-16 CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR part 15B |
PWR-IE50W-AC-IEC= |
EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, EN62368-1: 2014 + A11: 2017 CE |
EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-8, EN 61000-4-11 IEC61000-4-11, IEC61000-4-12, IEC61000-4-16 CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR part 15B |
PWR-IE65W-PC-AC= |
EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, EN61131-2: 2007 EN62368-1: 2014 + A11: 2017 IEC60950-1: 2005+A1: 2009+A2: 2013 IEC62368-1: 2014 UL 508 Class 1, Div 2/ Zone 2 Hazardous location CE UL60950-1 and CSA60950-1 certified |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, IEC61000-3-3, EN/IEC61000-4-11, IEC61000-4-12, EN61131-2: 2007 CISPR 32, EN 55032, CISPR35, EN55035 FCC47 CFR part 15B IEC 61850-3, IEEE1613 EN 61000-6-4, EN 61000-6-2 |
PWR-IE65W-PC-DC= |
EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 UL 508 Class 1, Div2/ Zone 2 Hazardous Location CCC CE |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR part 15B IEC 61850-3, IEEE1613 EN 61000-6-4, EN 61000-6-2 |
PWR-IE170W-PC-AC= |
IEC60950-1: 2005+A1: 2009+A2: 2013 EN60950-1: 2006+A1: 2010+A11: 2009 +A12: 2011+A2: 2013, KCC mark, BSMI mark, CCC, CB Scheme, Class 1, Div2/ Zone 2 Hazardous Location CE UL60950-1and CSA60950-1 certified |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, IEC61000-3-3, EN/IEC61000-4-11, IEC61000-4-12 CISPR 32, EN 55032, CISPR35, EN55035 47 CFR FCC part 15B EN61131-2: 2007 IEC 61850-3, IEEE 1613 EN50121-4:2016 |
PWR-IE170W-PC-DC= |
EN 60950-1: 2006 + A11:2009 + A1:2010 + A12:2011 + A2:2013 UL 508 Class 1, Div 2/Zone 2 Hazardous location CE |
EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR part 15B IEC 61850-3, IEEE1613 EN 61000-6-4, EN 61000-6-2 |
PWR-IE240W-PCAC-L= |
SIQ Bauart to EN 60950-1 UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme to IEC 60950-1 UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) CSA C22.2 No. 107.1-01 (File No. 181564) |
EN 61000-3-2 Class A, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2, EN 61204-3, EN 55024 (EN 61000-4-2 LEVEL 3, Performance Criteria A and EN 61000-4-3,4,5,6,8,11,12) CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR Part15B |
PWR-IE480W-PCAC-L= |
SIQ Bauart to EN 60950-1 UL/cUL recognized to UL 60950-1 and CSA C22.2 No. 60950-1 UL/cUL recognized to UL 62368-1 and CSA C22.2 No. 62368-1 CB scheme to IEC 60950-1 UL 508 and CSA C22.2 No. 107.1-01 (File No. E315355) CSA C22.2 No. 107.1-01 (File No. 181564) |
EN 61000-3-2 Class A, EN 61000-3-3, EN 61000-6-1, EN 61000-6-2, EN 61204-3, EN 55024 (EN 61000-4-2 LEVEL 3, Performance Criteria A and EN 61000-4-3,4,5,6,8,11,12) CISPR 32, EN 55032, CISPR35, EN55035 FCC 47 CFR Part 15B |
Product ID |
Dimensions (W x H x D) |
Unit weight |
MTBF (Telcordia SR-332) |
PWR-IE50W-AC-L= |
30 mm x 75 mm x 89.5 mm 1.18 in x 2.95 in x 3.52 in |
0.39 lb (0.18 kg) |
2,255,613 hours |
PWR-IE50W-AC= |
51 mm x 118 mm x 148 mm 2 in x 4.64 in x 5.82 in |
1.41 lb (0.64 kg) |
1,662,359 hours |
PWR-IE50W-AC-IEC= |
51 mm x 118 mm x 148 mm 2 in x 4.64 in x 5.82 in |
1.43 lb (0.65 kg) |
1,662,359 hours |
PWR-IE65W-PC-AC= |
66 mm x 148 mm x 118 mm 2.5 in x 5.82 in x 4.64 in |
2.64 lb (1.2 kg) |
2,488,401 hours |
PWR-IE65W-PC-DC= |
66 mm x 150 mm x 117 mm 2.59 in x 5.90 in x 4.60 in |
2.60 lb (1.18 kg) |
4,802,673 hours |
PWR-IE170W-PC-AC= |
96 mm x 150 mm x 146 mm 3.77 in x 5.90 in x 5.74 in |
3.88 lb (1.76 kg) |
2,384,975 hours |
PWR-IE170W-PC-DC= |
114 mm x 150 mm x 146 mm 4.48 in x 5.90 in x 5.74 in |
3.68 lb (1.67 kg) |
2,164,641 hours |
PWR-IE240W-PCAC-L= |
85 mm x 121 mm x 124.1 mm 3.34 in x 4.76 in x 4.88 in |
2.11 lb (0.96 kg) |
1,579,900 hours |
PWR-IE480W-PCAC-L= |
144 mm x 121 mm x 118.6 mm 5.66 in x 4.76 in x 4.66 in |
3.02 lb (1.37 kg) |
1,058,750 hours |